    Product Details:

    Place of Origin: CHINA
    Brand Name: BELONG
    Certification: ETL CE GS FCC
    Model Number: QY500H-VC3612

    Payment & Shipping Terms:

    Minimum Order Quantity: 1
    Price: Price negotiable
    Packaging Details: Carton & Pallet
    Delivery Time: Safety stock, 3 days-4 weeks
    Payment Terms: T/T
    Contact Now
    Detailed Product Description
    Microprocessor Control: Charging Process Fully Controlled By Microprocessor. Intelligent: Pre-charge, Constant Current, Constant Voltage, Automatic Power Off Once Charging Completed.
    Multiple Protection: Over Voltage, Under Voltage, Voltage-limiting, Over Current, Short-circuit, Reverse Polarity, Thermal Protection. High Efficiency: > 90% Conversion Efficiency, Power Factor>0.95, Efficient Environmental Protection.
    Compatibility: Compatible With Lead-acid, Gel, AGM And Lithium Batteries Safe & Reliable: All Aluminum Shell, Strong And Durable.
    Certificates: ETL CE GS FCC.

    Belong intelligent battery charger for cleaning & sweeping machine

    QY500H-VC3612 36V12A 540W

    1. General Information

     

    AC/DC 36V12A intelligent charger, 120&220Vac rated input voltage, 100-240Vac input voltage range, 44.1V/12A output, 540W max output power.

     

    Protections against Over-voltage and Under-voltage on input; Over-voltage, Under-voltage and Current-Limiting on output; Overheating, Reverse Polarity and Short Circuits.

     

    2. Specification

     

     

    Max Output Power Input Voltage Output Voltage Output Current
    540W 100~240Vac 43.8~44.4Vdc 10A~12A

     

     

     

     

    3. Electrical Characteristics

     

     

    Input Item Technical Standard Unit Note
    Rated Input Voltage 120/220 Vac  
    Input Voltage Range 100~240 Vac  
    Input Frequency Range 47~63 Hz  
    Max Input Current ≤6 A Rated load, and min input voltage
    Input Power Factor >0.95   Rated load
    Item Technical Standard Unit Note
    Output Output Voltage 44.1V Vdc  
    Output Current Range 44.1V 10 ~ 12 A  
    Voltage Precision

     

    44.1V

    ±0.3 Vdc  
    Output Ripple and Noise

     

    44.1V

    ≤(Vo X 0.5%)Vp-p mV  
    Power-on Output Delay

     

    44.1V

    ≤5 S  

    Output

    Rise Time

     

    44.1V

    ≤100 mS  
    On/Off Overshoot Amplitude

     

    44.1V

    ≤(Vo X 5%)Vp-p V Rise to 90%Vo from 10%Vo, rated load
    Recovery Time ≤200 uS  
    Overall Efficiency >90 %

    Rated Vin=120/220Vac,

    Rated output current=12A

    Output Power Off Hold Time ≥20 mS  
    TEMPCO ±3 mV/℃ Negative temperature coefficient compensation

    Protection

    Alarm

    &

    Indicator

     

    Item Technical Standard Unit Note
    Output OVP ≤(rated Vo) x110% V

    Recover automatically

    after the output returns to normal

     

    Output CLP

    ≤(rated Io) x110% A No auto recovery, current limiting or constant power output. Output interrupts are not allowed
    Output SCP Io= 0A A Auto recovery
    Input OVP >265 Vac Auto recovery
    Input Overvoltage Recovery <260 Vac
    Input UVP <85 Vac Auto recovery
    Input Undervoltage Recovery >90 Vac
    DC Output Indicator (ACT) Normal Output (LED)    

    Red

    LED

    Yellow LED Green LED
    Standby ON OFF OFF    
    Less than 50% charged Slow Flash(1/S) OFF OFF    
    50%-75% charged OFF Slow Flash(1/S) OFF    
    75%-100% charged

     

    OFF

     

    OFF

    Slow Flash(1/S)    
    100% fully charged OFF OFF ON    
    Power Failure Indicator (ALM)

    Abnormal Output (LED)

     

       

    Red

    LED

    Yellow LED Green LED

     

    Battery Failure

    Fast Flash(2/S)

     

    OFF

     

    OFF

       
    OTP OFF Fast Flash(2/S) OFF    

     

    Inner Failure

     

    OFF

     

    OFF

    Fast Flash(2/S)    
    Safety Requirement Item Test Condition Note
    VISO In-Out 2500Vac/5mA/1min No flashover or breakdown (Remove lightning protection devices in testing.)
    In-GND 2500Vac/5mA/1min
       

     

    RISO

    In-Out ≥100MΩ@500Vdc Remove lightning protection devices in testing.
    In-GND ≥100MΩ@500Vdc
    Out-GND ≥100MΩ@500Vdc
    LC In-GND ≤3.5mA Vin=264Vac/50Hz
    RG -- ≤0.1Ω  
    Temp Rise Overall unit Key components: IEC60950/GB4943; Others: within its own normal operating temperature range Full load, and at the worst ambient temperature
    Flame retardancy PCB GB4943.1/ IEC60950-1 V-0  
    Other isolation material GB4943.1/ IEC60950-1 V-1  
    EMC EMI (CE) EN55014-1:2017  
    (RE) EN55014-1:2017/CISPR22 CLASS B  
    (Harmonic Current) EN61000-3-2: 2014  
    EMS (ESD) EN61000-4-2:2009  
    (RS) EN61000-4-3:2010  
    (EFT) EN61000-4-4:2012  
    (SURGE) EN61000-4-5:2014  
    (CS) EN61000-4-6:2014  
    (MS) EN61000-4-8:2010  
    (DIP) EN61000-4-11:2004  

     

     

    4. Environmental Condition

     

     

    Item

     

    Technical Standard

     

    Unit

     

    Note

    Storage Temp -40~+85 Storage for 24h, recover for 2h at AT
    Operation Temp -25~+45  
    RH 5~90 % Non-condensing
    Heat Dissipation Intelligent air cooling    
    Altitude ≤3000 m  
    Pressure 70~106 kPa  
    MTBF ≥200000 h Bellcore TR-332(Ta=25°C)
    Vibration Random vibration: 5-500Hz in 3 mutually perpendicular directions, 1m2/s3 at 5-10Hz, 3 m2/s3 at 10-200Hz, and 1m2/s3 at 200-500Hz, 20min per direction   Normal working after testing.

    Working vibration

    Frequency: 5-9Hz, 9-200Hz

    Amplitude: 1.5mm

    Acceleration: 5m/s2

    Time: 5-200Hz-5Hz at each axis, 5 cycles in total

      Normal working during testing.
    Shock

    Shock Waveform: half sinusoid

    Peak acceleration: 60m/s2

    Cycle: 11ms

    Times: ±3 times at each axis, 18 times in total

      Normal working during testing.

     

    5. Mechanical characteristics

     

          Shell material: Aluminum Alloy

    Outline dimension: L*W*H=140*130*100mm

    Input socket: meets IEC standard

    AC wires: 1.5m length

    DC wire: 1.0m length

    Output connector: 50A red Anderson connector or equivalent

    Net Weight: 2.0Kg

     

    6. Charging Curve

     

    Belong intelligent battery charger for cleaning & sweeping machine QY500H-VC3612 36V12A 540W

    Lithium battery charging curve

    Belong intelligent battery charger for cleaning & sweeping machine QY500H-VC3612 36V12A 540W

    Lead-acid battery charging curve

     

    7. Application

    Belong intelligent battery charger for cleaning & sweeping machine QY500H-VC3612 36V12A 540WBelong intelligent battery charger for cleaning & sweeping machine QY500H-VC3612 36V12A 540WBelong intelligent battery charger for cleaning & sweeping machine QY500H-VC3612 36V12A 540W

    Contact Details
    BELONG INTERNATIONAL CO.,LTD

    Contact Person: Mr. Winter Teng Email: sales@belong-inc.com

    Tel: 86-21-51993699

    Send your inquiry directly to us (0 / 3000)